SCOPE of ACCREDITATION to ISO/IEC 17025: 1999
RADIOMETRICS MIDWEST CORPORATION
12 E. Devonwood
Romeoville, IL 60446
ELECTRICAL (EMC)
Valid To: February 28, 2005 Certification Number 1495-01
In recognition of the successful completion of the A2LA evaluation process, accreditation has been granted to this laboratory to perform the following electromagnetic compatibility tests:
|
Technology |
Test Methods |
Radiated Emissions Measurements E-field 10k-18 GHz |
CFR 47, FCC Part 15 (ANSI C63.4:1992); CFR 47, FCC Part 18 (FCC MP-5: 1986); CENELEC EN55022:1998, EN55011:1998; IEC CISPR 11: 2003; CISPR 22: 1997; Telcordia
GR-1089-CORE 2002 Section 3.2.1; MIL-STD-462E 1999 (Method RE102); RTCA DO160D 1997 (Section 21); ISO 7176-21:2003-4-15; AS/NZS 3548 CISPR 22:2002 |
|
Radiated Emissions Measurements H-field 30Hz-30 MHz
|
CFR 47, FCC Part 15 (ANSI C63.4:1992); CFR 47, FCC Part 18 (FCC MP-5: 1986); Telcordia GR-1089-CORE
2002
Section 3.2.1.2; MIL-STD-462E 1999 (Method RE101) |
|
Conducted Emissions Measurements (LISN 10k-400MHz) |
CFR 47, FCC Part 15 (ANSI C63.4:1992); CFR 47, FCC Part 18 (FCC MP-5: 1986); CENELEC EN55022:1998, EN55011:1998; IEC CISPR 11: 2003; CISPR 22: 1997; Telcordia GR-1089-CORE
2002
Section 3.2.2; MIL-STD-462E 1999 (Method CE102); ISO 7176-21:2003-4-15; AS/NZS 3548 CISPR 22:2002 |
|
Conducted Emissions Measurements (Current probe 10Hz-1000MHz) |
Telcordia GR-1089-CORE
2002
Section 3.2.3.1; MIL-STD-462E 1999 (Method CE101); RTCA DO160D 1997 (Section 21); |
|
Electrostatic Discharge Immunity |
CENELEC EN61000-4-2:2001; RTCA DO160D 1997 Section 25; ISO 7176-21:2003-4-15; |
|
Immunity Radiated E-field 10kHz to 18 GHz |
CENELEC EN61000-4-3; 2003 (80-1000MHz only), Telcordia GR-1089-CORE 2002 Part 3.3.1; ISO 7176-21;2003-4-15 (Anechoic Chamber Method); MIL-STD-462D 1993 (Method RS103); MIL-STD-462E 1999 (Method RS103); RTCA DO160D 1997 (Sections 20 change 1:2000); |
|
Immunity Radiated H-field 30 Hz to 100 kHz |
MIL-STD-462D 1993 (Method RS101); MIL-STD-462E 1999 (Method RS101); CENELEC EN61000-4-8: 2001 |
|
Immunity Conducted 30Hz to 400 MHz |
Telcordia GR-1089-CORE 2002 Part 3.3.2 & 3.3.3; MIL-STD-462D 1993 (Method CS101, CS114); MIL-STD-462E 1999 (Method CS101, CS114); RTCA DO160D 1997 (Sections 18 change 1:2001 and section 20 change 1:2000); CENELEC EN61000-4-6: 2003 |
|
Voltage Dips, Short Interruptions and Voltage Variations |
CENELEC EN61000-4-11:2001; RTCA DO160D 1997 Section 16 (Change 2:2001) |
|
Electrical Fast Transient Immunity |
CENELEC EN61000-4-4: 1995; CENELEC EN61000-4-4: Amd A1:2001 & A2:2001 |
|
Surge Immunity & Voltage Spikes |
CENELEC EN61000-4-5: 2001; RTCA DO160D 1997 Section 17 |
|
Harmonic Current Emissions |
CENELEC EN61000-3-2: 2001 |
|
Voltage Fluctuation and Flicker |
CENELEC EN61000-3-3: 1995 |
|
Induced Signal Susceptibility |
RTCA DO160D 1997 Section 19 |
|
Lightning Induced Transient Susceptibility |
RTCA DO160D 1997 Section 22 (Change 3:2002) |
|
Vehicle level RF Immunity |
SAE J551-11:2000; ISO 11451-2:2001 |
|
Vehicle RF Radiated Emissions |
SAE J551/2 1994; IEC CISPR 12:2001 |
|
Vehicle Component RF Emissions |
SAE J1113-41; IEC CISPR 25:2002 (ASLE method) |
|
Vehicle Component Level RF Immunity |
SAE J1113-21:1998; ISO 11452-2:2003 |
|
Vehicle Immunity to Transients (Waveform 2B, 4, 5A only) |
SEA J1113-11:2000; ISO 7637-2:2003 |
|
Screening Attenuation Measurements by Reverberation Chamber Method |
IEC 61726:2001 |
|
Electricity Meters Code of Electricity Metering (Basic Radiation Susceptibility only) |
ANSI C12.1:2001 (Section 4.7.3.12.1, Anechoic chamber method only) |