TESTING SERVICES - Military
As a veteran owned company Radiometrics has excelled as a Military EMC facility. Tests have been performed for all military branches both domestic and international. The demands of high level engineering expertise are always met. Our NARTE certified engineers are present for all testing and mitigation. Military EMC testing is also within our scope of accreditation from A2LA.
a. Mil-Std 461/462
| i. |
 |
CE101 Conducted Emissions, power leads
30 Hz to 10 kHz |
| ii. |
CE102 Conducted Emissions, power leads
10 kHz to 10 MHz |
| iii. |
CE106 Conducted Emissions, antenna terminals
10 kHz to 40 GHz |
| iv. |
CS101 Conducted Susceptibility, power leads
30 Hz to 50 kHz |
| v. |
CS103 Conducted Susceptibility, antenna port, intermodulation, 15 kHz to 10 GHz |
| vi. |
CS104 Conducted Susceptibility, antenna ports, rejection of undesired signal,
30 Hz to 20 GHz |
| vii. |
CS105 Conducted Susceptibility, antenna ports, cross modulation,
30 Hz to 20 GHz |
| viii. |
CS109 Conducted Susceptibility, structural current, 60 Hz to 100 kHz |
| ix. |
CS114 Conducted Susceptibility, bulk cable injection, 10 kHz to 400 MHz |
| x. |
CS115 Conducted Susceptibility, bulk cable injection, impulse excitation |
| xi. |
CS116 Conducted Susceptibility, damped sinusoidal transient,
cable and power leads, 10 kHz to 100 MHz |
| xii. |
RE101 Radiated Emissions, magnetic fields
30 Hz to 100 kHz |
| xiii. |
RE102 Radiated Emissions, electric fields
10 kHz to 18 GHz |
| xiv. |
RE103 Radiated Emissions, antenna spurious and harmonics, 10 kGHz to 40 GHz |
| xv. |
RS101 Radiated Susceptibility, magnetic fields
30 Hz to 100 kHz |
| xvi. |
RS103 Radiated Susceptibility, electric fields
10 kHz to 40 GHz |
| xvii. |
RS105 Radiated Susceptibility, transient electromagnetic fields |
b. Ministry of Defence, Defence Standard 59-41
 
| i. |
 |
DCE01, Conducted Emissions on Primary Power Lines, 20 Hz – 150 MHz |
| ii. |
DCE02, Conducted Emissions on Control, Signal and Power Lines, 20 Hz to 150 MHz |
| iii. |
DCE03, Export Transients, Primary Power Lines |
| iv. |
DCS01, Conducted Susceptibility, Primary Power Lines, 20 Hz to 50 kHz |
| v. |
DCS02, Conducted Susceptibility, Power, Control and Signal Lines, 50 kHz 400 MHz |
| vi. |
DCS03, Conducted Susceptibility, Control and Signal, 20 Hz – 50 kHz |
| vii. |
DCS04, Conducted Susceptibility, Imported Transient Susceptibility (Aircraft) |
| viii. |
DCS05, Conducted Susceptibility, Externally Generated Transients
(Land and Sea Systems) |
| ix. |
DCS06, Conducted Susceptibility, Imported Long Transient susceptibility
(Land and Sea Services), AC and DC Systems |
| x. |
DCS08, Conducted Susceptibility, Externally Generated Transients (Aircraft) |
| xi. |
DCS09, Conducted Susceptibility, Imported Lightning Transient Susceptibility (Aircraft) |
| xii. |
DCS10, Conducted Susceptibility, Electrostatic Discharge (ESD) |
| xiii. |
DCS12, Conducted Susceptibility, Imported Low Frequency Transient
Susceptibility – Power Lines (Sea Systems) |
| xiv. |
DRE01, Electric (E) Field Radiated Emissions, 14 kHz to 18 GHz |
| xv. |
DRE02, Magnetic (H) Field Radiated Emissions, 20 Hz to 100 kHz |
| xvi. |
DRE03, Radiated Emissions Installed Antenna, 1.6 MHz to 76 MHz |
| xvii. |
DRS01, Magnetic (H) Field Susceptibility, 20 Hz to 100 kHz |
| xviii |
DRS02, Electric (E) Field Susceptibility, Standard Method, 10 kHz to 18 GHz |
| xix |
DRS03, Magnetic Field (DC) Susceptibility, Land and Sea Systems |
We understand that many development projects are unique and the above set of standards may not always directly apply. Alternate tests are available. Our staff is on call to assist you in selecting, developing and executing any special needs.
|
|